-40%

5IN1 40K Cavitation Ultrasonic RF Vacuum Full Body Slimming Machine Fat Removal

$ 171.6

Availability: 397 in stock
  • Brand: Unbranded
  • Return shipping will be paid by: Buyer
  • Marque: Does not apply
  • 510(k) Number: K161892
  • Item must be returned within: 60 Days
  • Refund will be given as: Money Back
  • All returns accepted: Returns Accepted
  • Condition: New
  • Restocking Fee: No
  • Numéro de pièce fabricant: Does not apply
  • 510(k) Number :: K161892
  • MPN: Does not apply

    Description

    Store Categories
    Store Categories
    Patient Monitor
    Fetal Monitor
    Multi-parameter Patient Monito
    Ultrasound Scanner
    RUS-9000E2
    RUS-9000F
    RUS-9000B
    RUS-6000A
    RUS-6000D
    Color dopplar
    RUS-9000A
    Endoscope
    Rigid Endoscope Kit
    Laparoscope Kit
    Cystoscope Kit
    Arthroscope Kit
    Sinuscope Kit
    Hysteroscope Kit
    Otoscope Kit
    Laryngoscope Kit
    Electronic Colposcope
    Laparoscopy Instruments
    Light Source & Cable
    Gynaecology
    Endoscope Camera
    Health Care
    Pulse Oximeter
    Fetal Doppler
    Blood Pressure Monitor /ABPM
    Spirometer
    Vascular Doppler
    Oxygen Concentrator/Generator
    Stethoscopes
    EEG ECG EKG Holter
    Holter
    PC-ECG
    Electrocardiograph / ECG/ EKG
    EEG
    ABPM
    Dental Equipment
    Curing Light
    Dental Handpieces
    High speed
    Low speed
    Dental Handpiece Kit
    Inner Water Handpiece
    Dental Cartridge
    LED handpiece
    Dental Loupes and Headlamps
    Dental Intraoral Camera
    Ultrasonic Scaler
    Dental Autoclave Sterilizer
    Apex Root Locators
    Dental Endo Motor
    3-Way Syringe
    Teeth Whitening Bleaching
    Prophy Jet Handpeice
    Dental Polishing Micro Motor
    Dental Orthodontics
    Dental Unit for Clinic
    Teeth Model
    Dental bur & Bolck
    Oral care for Home
    Dental instruments
    Dental lab equipment
    Dental Special
    Dental Suplies
    X-Ray
    Rod Tips
    Oral Care for Home
    Pump
    Electrosurgical Unit
    Sex Health
    Jewelry & Watch
    Pet Supplies
    Stage light
    Veterinary
    ego
    Outdoor Product
    3C Products
    Household goods
    Hearing Assistance
    Clothes & Shoes & Socks
    Bags
    Business & Industry
    Beauty Machine & Home Medical
    Beauty Salon
    Household Medical
    Motor parts
    Maternal & Toys
    Other
    5IN1 40K Cavitation Ultrasonic RF Vacuum Full Body Slimming Machine Fat Removal
    Product View
    Detail
    Description:
    Instrument Function and Treatment Principles
    1.Bipolar RF handle for eyes
    Stick to enhance rejuvenation: use of positive and negative micro-current activation energy release skin cells, so that rapid  synthesis of fibroblasts Collagen, elastic skin revert to the original compact, the skin causing t the skin to stimulate the muscle tension is increased, thereby gradually   eliminate wrinkles, prevent skin aging, restoring skin elasticity, facial improvement.
    2. Sextupole RF handle
    Being integrated with the most advanced RF technology and radio frequency, the instrument may directly reach the deep-seated fat body and have the excellence of targeted positioning RF. In the fast-active state, fat cell tissue may generate friction heat, increase local temperature and remove excess fat and toxin from the body through sweat gland, enterohepatic circulation and lymph and ultimately achieve the effect of dissolving fat. With controlled depth technology, inlaid diamond  particles of different sizes  may rub skin alongits pattern, adjust suction strength by means of vacuum draw and rub with negative pressure strongforce to directly explode thick fat. Thus, the effects are very obvious: Enhance blood circulation, accelerate the decomposition of fat, take  away wastes, enhance the effect of removing cellulite, effectively improve the state of areolar  tissue, remove stubborn fat and improve the  sufficient absorption condition of diet products.
    3. Quadrupole RF handle --Facial wrinkle elimination, tightening and lifting
    A capacitive coupling electrode is used for transmitting radio-wave energy and generating an  electric field for entering into subcutaneous tissue through the skin surface. In the high-frequency
    Of 450khz, this electric field changes its polarity for 450,000 times per second. To reply to the rapid   change in electrode, directions of electrical particles the skin are also changed. By this time, natural electric resistance in thesubcutaneous tissue moves and generates heat energy. As thepapillary dermis collagen may immediately shrink when the temperature is within the range from 60 to 70 Celcius degree, after wrinkle treatment, client may immediately sense the skin tightening effects  as it is being lifted and firmed. When collagen is produced continuously, thickness and density of the skin papillary dermis may be increased to remove wrinkles, eliminate scars, restore skin elasticity and gloss and make it be blonde and smooth. While collagen is increased, fresh skin is  generated in the position of operation and wrinkles are removed by large amount of cells. In addition, when cortex without elasticity or that with thick horny layer in the area with wrinkles is separated, surrounding skin will also be renewed.
    4. Tripolar facial handle
    Stick to enhance rejuvenation: use of positive and negative micro-current activation energy release skin cells, so that rapid  synthesis of fibroblasts Collagen, elastic skin revert to the original compact, the skin causing t the skin to stimulate the muscle tension is increased, thereby gradually   eliminate wrinkles, prevent skin aging, restoring skin elasticity, facial improvement.
    Caution for using RF
    1. Beautician should wear insulated gloves during operation.
    2. Do not wear any aglet, both for the beautician and the users.
    3. The electrode probe must be fully in contact with skin.
    4. Do not make the RF electrode stay on any part without moving. Keep it moving on skin slowly.
    5. Skin around eyes and forehead is very thin, the RF output intensity should be relatively weakened.
    6. Do not contact skin with unipolar when using of bipolar, tripolar, hexpolar RF work head otherwise it will produce pulse discharge, gel paste etc. Products like gel maybe evaporated into a mist.
    Using Guidance
    1. Sextupole RF laser work head for body
    Waist and abdomen care

    25minutes

    2-3 days/time

    Massage to navel as center and gradually expanding the range
    Massage chest nest, both sides of former abdomen and below the navel(into diamond) from inside to outside in circles.
    Concentrated the fat from 4 directions to navel as center.
    Massage from end of pelvis to groin in circles.
    Massage from inner rib to outer edge in circles.
    Massage back and forth from inner rib to outer edge in straight line
    LiftiHip and he lower part of the body care

    30minutes

    2-3days/time

    used the
    Φ
    D50mm probe
    Concentrated the fat to groin in circles or straight line.ng from inner rib to outer edge after massage
    2. Tripolar RF work head for face
    Massage the mandible center in circles to produce deep heat.
    Massage lower jaw in lines.
    Massage the triangle zone of both sides of the face in circles.
    Massage from jaw to angulus oris to ear in lines.
    Massage from jaw to angulus oris to ear in lines.
    ADVERTION
    1.      Pregnant women or women during in menses.
    2.      Epileptic
    3.      Patients with malignancy.
    4.      Patient whose wound after operation has not healed up.
    5.      Acute inflammation or epidemical patients.
    6.      Whom with heart diseases or with heart pacemaker.
    7.      Whom with kidney (gall-stone) disease
    8.      Who was embedded metal object or silica gel.
    9.      Who in menses, birth control period, emiction incontinence period, or accepting the belly operation.
    10.   Whose body always take much inner hot.
    11.   Who has the genetic hypersensitivity.
    NOTICE
    1.      Be sure to use the special gel .
    2.      Avoid knocking the us head.
    3.      For avoiding burning the head, during operation, please prepare enough gel.
    4.      Don’t stay in one place, avoid treating on the bone.
    5.      Don’t use disinfectant product to disinfect the us head. We suggest the wet cotton or dry towel enough.
    6.      Check the machine power cord if it is connected well.
    7.      If the machine will not use for a loing time, please switch off it, and power off.
    8.      Please take off all metal decoration from the operator and patient’s body.
    9.      If continuous using 1 hour, please pause the machine about 10 minutes, then using again.
    10.   During the operation, be sure not to accept other treatment.
    Package Including
    Multipolar RF Head for Body x 1
    40KHz Cavitation Head x 1
    Vacuum Biploar RF Head x1
    Tripolar RF Head for Faceand eyes' around x 1
    Quadrupole RF Head for Face and Body x 1
    Power cord x 1
    Shipping Policy
    Payment Method
    Returns Policy
    Shipping Policy
    Payment Method
    Returns Policy
    Copyright © 2017 DataCaciques
    Store Categories
    Store Categories
    Patient Monitor
    Fetal Monitor
    Multi-parameter Patient Monito
    Ultrasound Scanner
    RUS-9000E2
    RUS-9000F
    RUS-9000B
    RUS-6000A
    RUS-6000D
    Color dopplar
    RUS-9000A
    Endoscope
    Rigid Endoscope Kit
    Laparoscope Kit
    Cystoscope Kit
    Arthroscope Kit
    Sinuscope Kit
    Hysteroscope Kit
    Otoscope Kit
    Laryngoscope Kit
    Electronic Colposcope
    Laparoscopy Instruments
    Light Source & Cable
    Gynaecology
    Endoscope Camera
    Health Care
    Pulse Oximeter
    Fetal Doppler
    Blood Pressure Monitor /ABPM
    Spirometer
    Vascular Doppler
    Oxygen Concentrator/Generator
    Stethoscopes
    EEG ECG EKG Holter
    Holter
    PC-ECG
    Electrocardiograph / ECG/ EKG
    EEG
    ABPM
    Dental Equipment
    Curing Light
    Dental Handpieces
    High speed
    Low speed
    Dental Handpiece Kit
    Inner Water Handpiece
    Dental Cartridge
    LED handpiece
    Dental Loupes and Headlamps
    Dental Intraoral Camera
    Ultrasonic Scaler
    Dental Autoclave Sterilizer
    Apex Root Locators
    Dental Endo Motor
    3-Way Syringe
    Teeth Whitening Bleaching
    Prophy Jet Handpeice
    Dental Polishing Micro Motor
    Dental Orthodontics
    Dental Unit for Clinic
    Teeth Model
    Dental bur & Bolck
    Oral care for Home
    Dental instruments
    Dental lab equipment
    Dental Special
    Dental Suplies
    X-Ray
    Rod Tips
    Oral Care for Home
    Pump
    Electrosurgical Unit
    Sex Health
    Jewelry & Watch
    Pet Supplies
    Stage light
    Veterinary
    ego
    Outdoor Product
    3C Products
    Household goods
    Hearing Assistance
    Clothes & Shoes & Socks
    Bags
    Business & Industry
    Beauty Machine & Home Medical
    Beauty Salon
    Household Medical
    Motor parts
    Maternal & Toys
    Other
    Detail
    [Product Video]
    Video will open in a new window
    Description:
    Instrument Function and Treatment Principles
    1.Bipolar RF handle for eyes
    Stick to enhance rejuvenation: use of positive and negative micro-current activation energy release skin cells, so that rapid  synthesis of fibroblasts Collagen, elastic skin revert to the original compact, the skin causing t the skin to stimulate the muscle tension is increased, thereby gradually   eliminate wrinkles, prevent skin aging, restoring skin elasticity, facial improvement.
    2. Sextupole RF handle
    Being integrated with the most advanced RF technology and radio frequency, the instrument may directly reach the deep-seated fat body and have the excellence of targeted positioning RF. In the fast-active state, fat cell tissue may generate friction heat, increase local temperature and remove excess fat and toxin from the body through sweat gland, enterohepatic circulation and lymph and ultimately achieve the effect of dissolving fat. With controlled depth technology, inlaid diamond  particles of different sizes  may rub skin alongits pattern, adjust suction strength by means of vacuum draw and rub with negative pressure strongforce to directly explode thick fat. Thus, the effects are very obvious: Enhance blood circulation, accelerate the decomposition of fat, take  away wastes, enhance the effect of removing cellulite, effectively improve the state of areolar  tissue, remove stubborn fat and improve the  sufficient absorption condition of diet products.
    3. Quadrupole RF handle --Facial wrinkle elimination, tightening and lifting
    A capacitive coupling electrode is used for transmitting radio-wave energy and generating an  electric field for entering into subcutaneous tissue through the skin surface. In the high-frequency
    Of 450khz, this electric field changes its polarity for 450,000 times per second. To reply to the rapid   change in electrode, directions of electrical particles the skin are also changed. By this time, natural electric resistance in thesubcutaneous tissue moves and generates heat energy. As thepapillary dermis collagen may immediately shrink when the temperature is within the range from 60 to 70 Celcius degree, after wrinkle treatment, client may immediately sense the skin tightening effects  as it is being lifted and firmed. When collagen is produced continuously, thickness and density of the skin papillary dermis may be increased to remove wrinkles, eliminate scars, restore skin elasticity and gloss and make it be blonde and smooth. While collagen is increased, fresh skin is  generated in the position of operation and wrinkles are removed by large amount of cells. In addition, when cortex without elasticity or that with thick horny layer in the area with wrinkles is separated, surrounding skin will also be renewed.
    4. Tripolar facial handle
    Stick to enhance rejuvenation: use of positive and negative micro-current activation energy release skin cells, so that rapid  synthesis of fibroblasts Collagen, elastic skin revert to the original compact, the skin causing t the skin to stimulate the muscle tension is increased, thereby gradually   eliminate wrinkles, prevent skin aging, restoring skin elasticity, facial improvement.
    Caution for using RF
    1. Beautician should wear insulated gloves during operation.
    2. Do not wear any aglet, both for the beautician and the users.
    3. The electrode probe must be fully in contact with skin.
    4. Do not make the RF electrode stay on any part without moving. Keep it moving on skin slowly.
    5. Skin around eyes and forehead is very thin, the RF output intensity should be relatively weakened.
    6. Do not contact skin with unipolar when using of bipolar, tripolar, hexpolar RF work head otherwise it will produce pulse discharge, gel paste etc. Products like gel maybe evaporated into a mist.
    Using Guidance
    1. Sextupole RF laser work head for body
    Waist and abdomen care

    25minutes

    2-3 days/time

    Massage to navel as center and gradually expanding the range
    Massage chest nest, both sides of former abdomen and below the navel(into diamond) from inside to outside in circles.
    Concentrated the fat from 4 directions to navel as center.
    Massage from end of pelvis to groin in circles.
    Massage from inner rib to outer edge in circles.
    Massage back and forth from inner rib to outer edge in straight line
    LiftiHip and he lower part of the body care

    30minutes

    2-3days/time

    used the
    Φ
    D50mm probe
    Concentrated the fat to groin in circles or straight line.ng from inner rib to outer edge after massage
    2. Tripolar RF work head for face
    Massage the mandible center in circles to produce deep heat.
    Massage lower jaw in lines.
    Massage the triangle zone of both sides of the face in circles.
    Massage from jaw to angulus oris to ear in lines.
    Massage from jaw to angulus oris to ear in lines.
    ADVERTION
    1.      Pregnant women or women during in menses.
    2.      Epileptic
    3.      Patients with malignancy.
    4.      Patient whose wound after operation has not healed up.
    5.      Acute inflammation or epidemical patients.
    6.      Whom with heart diseases or with heart pacemaker.
    7.      Whom with kidney (gall-stone) disease
    8.      Who was embedded metal object or silica gel.
    9.      Who in menses, birth control period, emiction incontinence period, or accepting the belly operation.
    10.   Whose body always take much inner hot.
    11.   Who has the genetic hypersensitivity.
    NOTICE
    1.      Be sure to use the special gel .
    2.      Avoid knocking the us head.
    3.      For avoiding burning the head, during operation, please prepare enough gel.
    4.      Don’t stay in one place, avoid treating on the bone.
    5.      Don’t use disinfectant product to disinfect the us head. We suggest the wet cotton or dry towel enough.
    6.      Check the machine power cord if it is connected well.
    7.      If the machine will not use for a loing time, please switch off it, and power off.
    8.      Please take off all metal decoration from the operator and patient’s body.
    9.      If continuous using 1 hour, please pause the machine about 10 minutes, then using again.
    10.   During the operation, be sure not to accept other treatment.
    Package Including
    Multipolar RF Head for Body x 1
    40KHz Cavitation Head x 1
    Vacuum Biploar RF Head x1
    Tripolar RF Head for Faceand eyes' around x 1
    Quadrupole RF Head for Face and Body x 1
    Power cord x 1
    Payment Method
    Shipping Policy
    Returns Policy
    About Warranty
    About US
    Payment Method
    We only accept payment via PayPal.
    FDA Disclaimer:
    Statement:The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.(CICI-China-86-18328503374)
    This item has been cleaned and treated according to the manufacturer's instructions.
    The Fingertip Pulse Oximeter is certified with the US FDA 510K No. K070371, the CE & TUV of Eureope and it is on the Australian Register of Therapeutic Goods (ARTG) with the code 136606.
    The Powered Surgical Instrument / Speed 808 System is certified with the US FDA 510(k) Number:K132989
    The Powered Surgical Instrument / Hair Remove Device is certified with the US FDA 510(k) Number:K180353
    The Powered Surgical Instrument / Hair Remove System is certified with the US FDA 510(k) Number:K141973
    massager, vacuum, light induced heating / Slimming Treatment Device is certified with the US FDA 510(k) Number:K161892
    Shipping Policy
    1.
    US Stock
    items Shipping Service UPS 3-5 BUSINESS DAYS (weekend and festival not included) from our warehouse in the US,
    only to United-States.
    China Stock
    items will be shipped by epacket
    or Airmail post within 1 business days.
    2.We are not Responsible for your Customs duty.
    3.
    We don't add taxes, VAT or other hidden charges. You pay us what you see on the invoice, i.e. goods subtotal + shipping cost (not include duties). Please find out as much as you can about your import taxes in your own country before bidding the item. You need to pay for the import duties in case that occurred for certain goods.
    Returns Policy
    1.If you receive a defective item which you want to return, please contact us when you receive the item.
    2.All return items must be returned with its original packaging and accessories. If we confirm the damage happened during the shipment, we will bear the shipping cost for return.
    3.We will refund the money to you when we get the return items. Or replace item for you free of charge.
    About Warranty
    We guarantees new equipment other than accessories to be free from defects in workmanship and materials for a period of twelve months (six months for spare parts) from the date of shipment under normal use and service. Our company's obligation under this warranty is limited to repairing, at our company's option, any part which upon our company's examination proves defective.
    About US
    Our working time: Monday - Friday   9:00 AM - 5:30PM (Beijing) we
    ship the package from Monday to Saturdays.